| Table 1: Work that need not be notified to building control bodies |
| Work consisting of: |
| Replacing accessories such as socket-outlets, control switches and ceiling roses |
| Replacing the cable for a single circuit only, where damaged, for example, by fire, rodent or impact (a) |
| Re-fixing or replacing the enclosures of existing installation components (b) |
| Providing mechanical protection to existing fixed installations (c) |
| Work that is not in a kitchen or special location and does not involve a special installation (d) and consists of: |
| Adding lighting points (light fittings and switches) to an existing circuit (e) |
| Adding socket-outlets and fused spurs to an existing ring or radial circuit (e) |
| Installing or upgrading main or supplementary equipotential bonding (f) |
| Notes |
| (a) On condition that the replacement cable has the same current carrying capacity, follows the same route and does not serve more than one sub-circuit through a distribution board |
| (b) If the circuit’s protective measures are unaffected |
| (c) If the circuit’s protective measures and current-carrying capacity of conductors are unaffected by increased thermal insulation |
| (d) Special locations and installations are listed in Table 2 |
| (e) Only if the existing circuit protective device is suitable and provides protection for the modified circuit, and other safety provisions are satisfactory |
| (f) Such work shall comply with other applicable legislation, such as the Gas Safety (Installation and Use) Regulations |
| Table 2: Special locations and installations (a) |
| Locations containing a bath tub or shower basin |
| Swimming pools or paddling pools |
| Hot air saunas |
| Electric floor or ceiling heating systems |
| Garden lighting or power installations |
| Solar photovoltaic (PV) power supply systems |
| Small-scale generators such as micro-CHP units |
| Extra-low voltage lighting installations, other than pre-assembled, CE-marked lighting sets |
| Notes |
| See IEE Guidance Note 7 which gives more guidance on achieving safe installations where risks to people are greater |