| Current thermal efficiency requirement for house elements | ||
| Exposed element | U-value with low-energy rating (W/m2 °C) | U-value with high-energy rating (W/m2 °C) |
| Roof | 0.2 | 0.25 |
| Wall | 0.45 | 0.45 |
| Exposed and ground floor | 0.35 | 0.45 |
| Semi-exposed wall and floor | 0.6 | 0.6 |
| Windows, doors and rooflights | 0.3 | 3.3 |
| Proposed thermal efficiency requirement for house elements 2001-2003 | ||||
| 2001 | 2003 | 2001 | 2003 | |
| Exposed element | U-value with efficient heating (W/m2 °C) | U-value with inefficient heating (W/m2 °C) | ||
| Pitched roof (with insulation between rafters) | 0.25 | 0.2 | 0.2 | 0.15 |
| Pitched roof (with insulation between joists) | 0.2 | 0.16 | 0.16 | 0.15 |
| Flat roof | 0.25 | 0.25 | 0.2 | 0.2 |
| Wall | 0.35 | 0.3 | 0.3 | 0.25 |
| Floor | 0.3 | 0.25 | 0.25 | 0.22 |
| Windows, doors and rooflights (overall average) | 2.2 | 2 | 2 | 1.8 |
| source: Working group document | ||||