Welcome to building.co.uk. This site uses cookies. Read our policy.

Table 1: LPC test results
Test Failure time from ignition (minutes) Comment
Heavyweight frame only 28 Frame failed and dislodged fire-resisting panels
Lightweight frame only 23 Frame failed and dislodged fire-resisting panels
Aluminium bracket only 29 Brackets withstood fire but panels were dislodged
Heavyweight frame with facade 11·5 Glazed elements failed and fire entered floor above
Lightweight frame with facade 13 Glazed elements failed and fire entered floor above
Lightweight frame with façade
(real furniture used as source of fire)
5 Glazed elements failed and fire entered floor above
Sprinkler on fire gases No failure Temperature was suppressed by water
Internal drenching of glazing 32 Glazing was dislodged but fire did not spread
External drenching of glazing 32 Glazing was dislodged but fire did not spread