- News

All the latest updates on building safety reformRegulations latest
- Focus

All the latest updates on building safety reform
| Sustainability costs | ||
| The following cost analysis by Davis Langdon provides indicative costs for various items of construction that can be incorporated in a building to boost its green credentials. Costs are the national average at first quarter 2004 price levels. | ||
| unit | £ | |
| Recycled aggregates | ||
| General fill material | ||
| Blast furnace slag | t | 5.30-8.00 |
| Quarry waste | t | 7.00-9.50 |
| Graded material | ||
| Crushed concrete | t | 5.25-7.50 |
| Brickwork | ||
| Extra for lime mortar in lieu of cement mortar | m2 | 3.50-5.00 |
| Curtain walling | ||
| Extra for manually openable windows | each | 300-350 |
| Extra for top-hung windows, electrically actuated | each | 600-750 |
| Solar shading | ||
| Externally mounted aluminium louvres | m2 | 150-250 |
| External automated fabric blinds, including controls, wind and light sensors | m2 | 275-325 |
| Rooflights | ||
| Extra for fixed rooflight costs for opening vents, tilt and turn, actuator motors | each | 750-1000 |
| Roof canopies | ||
| To reduce solar heat load and glare | m2 | 350-500 |
| Ceiling finishes | ||
| Self-finished acoustic plaster | m2 | 20-30 |
| Ventilation | ||
| Extract fans, wiring and controls | each | 650-750 |
| For a much wider consideration of sustainability issues and costs affecting commercial buildings, refer to Davis Langdon’s Sustainability Cost Model published in Building on 12 September 2003. | ||
| Specifiers who do not know the cost of recycled aggregates or solar shading need to buck up their ideas. The government is set to make sustainable specification a condition for building tens of thousands of homes (see Rules, page 17). And architects and designers who still believe that eco-building is just for hippies are in danger of missing out on a green building boom. | ||
| Total building energy costs £ per year | ||||
| Assumptions: | gas cost | 83 m2 gifa | electricity cost | |
| £0.014/kWh | £0.06/kWh | |||
| Building type | Heating | Hot water | Electricity | Total |
| Eco TekHaus | 23 | 35 | 80 | 138 |
| Standard TekHaus | 42 | 46 | 159 | 248 |
| Building regs 2002 | 75 | 58 | 199 | 333 |
| Existing Building | 267 | 70 | 249 | 586 |
| Note: Omits standing charges. | ||||
| Total building CO2 emissions kg per year | ||||
| Assumptions: | 80% heating efficiency | 107 m2 gifa | 0.19 kg CO2/kWh gas | 0.44 kg CO2/kWh electric |
| Building type | Heating | Hot water | Electricity | Total |
| Eco TekHaus | 503 | 762 | 753 | 2019 |
| Standard TekHaus | 920 | 1017 | 1507 | 3443 |
| Building regs 2002 | 1647 | 1271 | 1883 | 4801 |
| Existing building | 5845 | 1525 | 2354 | 9724 |
| Notes: kg CO2 figures are for 2000. Source: www.energy-efficiency.gov.uk/document/factfigs/emiss.htm. £ cost figures are from SAP. Assumes some off-peak electricity use. | ||||
| Heating costs £ per year | |||
| Assumptions: | gas cost | 107 m2 gifa | |
| £0.014/kWh | |||
| Building type | All out | All in | Half in |
| Eco TekHaus | 15 | 21 | 30 |
| Standard TekHaus | 29 | 49 | 54 |
| Building regs 2002 | 57 | 88 | 97 |
| Existing building | 217 | 322 | 345 |
| Heating CO2 emissions kg per year | |||
| Assumptions: | 80% heating efficiency | 107 m2 gifa | 0.285 kg CO2/kWh gas |
| Building type | All out | All in | Half in |
| Eco TekHaus | 385 | 534 | 755 |
| Standard TekHaus | 728 | 1246 | 1380 |
| Building regs 2002 | 1452 | 2230 | 2470 |
| Existing building | 5527 | 8196 | 8767 |
| Further assumptions | |||
| Heating energy use has been modelled in detail. | |||
| Electrical energy demand and Hot Water Demand is assumed to be reduced through design and specification to the same level as the thermal design in each case. | |||
| XCO2 has referred to monitored case studies where possible in making these assumptions. | |||
| Assumed 'worst case' scenario of half in occupancy. | |||