- News

All the latest updates on building safety reformRegulations latest
- Focus

All the latest updates on building safety reform



| Tough as old boots: The new U-values … | ||
| U-values for building envelope | 2002 version of Part L | Possible standards for 2005 |
| Roofs | 0.16 to 0.25 | 0.16 or 0.13 |
| External walls | 0.35 | 0.25 |
| Ground floors | 0.25 | 0.20 to 0.22 |
| The average of all windows, doors and rooflights | 2.0 to 2.2 | 1.80 |
| … and the new airtightness rules | ||
| Permeability (m3/h/m2 at 50 Pa) | ||
| Type of building | Current requirement | Possible requirement for 2005 |
| Naturally ventilated dwelling | 10 | 10 |
| Dwelling with balanced whole house ventilation | 10 | 5 |
| Naturally ventilated offices and retail | 10 | 10 |
| Offices and retail with balanced mechanical ventilation | 10 | 7 |
| Industrial and warehouses | 10 | 7 |