- News

All the latest updates on building safety reformRegulations latest
- Focus

All the latest updates on building safety reform



| Table 1 - Power distances for two twisted pairs | |||
| Voltage | Pcam (W) | Dist spec max (ft) | Dist spec max (m) |
| 12v AC or DC | 5 | 86 | 28 |
| 12v AC camera | 10 | 43 | 14 |
| 20 | 22 | 7 | |
| 30 | 14 | 5 | |
| 40 | 11 | 4 | |
| 50 | 9 | 3 | |
| 24v AC | 5 | 346 | 113 |
| 24v AC camera | 10 | 173 | 57 |
| 20 | 86 | 28 | |
| 30 | 58 | 19 | |
| 40 | 43 | 14 | |
| 50 | 35 | 11 | |
| 28v AC | 5 | 922 | 302 |
| 28v AC camera | 10 | 461 | 151 |
| 20 | 230 | 76 | |
| 30 | 154 | 50 | |
| 40 | 115 | 38 | |
| 50 | 92 | 30 | |
| Table 2 - Power distances for two twisted pairs | |||
| Voltage | Pcam (W) | Dist spec max (ft) | Dist spec max (m) |
| 12v AC or DC | 5 | 130 | 43 |
| 12v AC camera | 10 | 65 | 21 |
| 20 | 32 | 11 | |
| 30 | 22 | 7 | |
| 40 | 16 | 5 | |
| 50 | 13 | 4 | |
| 24v AC | 5 | 518 | 170 |
| 24v AC camera | 10 | 259 | 85 |
| 20 | 130 | 43 | |
| 30 | 86 | 28 | |
| 40 | 65 | 21 | |
| 50 | 52 | 17 | |
| 28v AC | 5 | 1382 | 454 |
| 28v AC camera | 10 | 691 | 227 |
| 20 | 346 | 113 | |
| 30 | 230 | 76 | |
| 40 | 173 | 57 | |
| 50 | 138 | 45 | |